ZAKUP MOBILNEGO LODOWISKA
Poland · Starogard Gdański · how to bid here →
Your path to submission
- Deadline: 12 October at 10:00 — 7 days left.
- You submit on eZamówienia — not here and not by e-mail. ↗ Submission via eZamówienia: account required; above the EU threshold a qualified signature, nationally the 'trusted signature' often suffices — check the wording. Sort out account and signature first — not on submission day.
- Collect your evidence — the eligibility requirements are listed above; for many of them the analysis explains how to obtain them.
Foreign bidders
In Poland · Industrial machinery, 89 contracts went to foreign companies over the last 3 years (of 7,213 recorded awards) — mostly from Germany, France, Italy.
Typical field: median 3 (from 1,565 awards).
What the buyer is looking for
1. The subject of the order is the delivery of a mobile ice rink. 2. Technical data of the ice rink: 1) ice rink designed for figure skating, curling, sliding, 2) type of ice rink: outdoor ice rink, 3) dimensions of ice rink ice plate: 40 m x 15 m, 4) season of use: December to February. 3. Refrigeration system for ice rink: 1) ice rink cooling system: the ordering party requires the supply of refrigeration pipes adapted to the dimensions of the ice rink (40x15m) made of EPDM mats to prevent waving; connection of collectors by means of quick couplers; 2) Coolant: aqueous solution of ethylene glycol (35%), 3) substrate insulation: a wooden frame should be prepared, in which a layer of sand will be spread between the two layers of protective film - the lower and the upper one - to level the ground, the upper layer of the film should completely cover the prepared and leveled layer of sand;…
Show full description
… 4) Cooling power supply: from a refrigeration unit located outside the ice rink; 5) flexible plastic hoses shall be used for the connection between the collector and the aggregate; 6) Band layout equipment: entrance gates for skaters with a width of min 0,8 m and gate for entry of rollers with a width of min 3,3 m; 7) control of aggregate parameters from the controller placed on the aggregate. 4. Refrigeration unit (technical parameters): 1) chiller cooling capacity: net cooling capacity min. 100,0 [kW]; 2) glycol temperature: - 9,0/-12,0 [0C]; 3) outdoor temperature +15 [0C]; (4) concentration of ethylene glycol : 35 [%]; 5) number of refrigeration circuits: min. 2; 6) scroll compressors: min. 4; 7) Performance regulation: 4 degrees; 8) Maximum sound power level: [dBA] +/- 2; 9) Sound pressure (10m): 60,0 [dBA] +/-2. 5. Before signing the contract, the Contractor must provide a declaration confirming the possibility of providing and delivering a replacement unit in the event of failure of the refrigeration unit, in order to ensure the continuity of the rink's operation. 6. The refrigeration unit must have the CE marking and the required declarations or certificates confirming the compliance of the equipment with the applicable requirements and standards. 7. The unit must be equipped with a programmable microprocessor control module, enabling optimization of the operation of the device in order to achieve the highest possible energy efficiency, without adversely affecting the quality of the ice rink and the durability of the device. 8. Description of the aggregate: 1) the electrical panel of the device must be resistant to atmospheric influences. The controller shall be capable of displaying information, changing and controlling the following: glycol and refrigerant temperature, refrigerant pressure, diagnostic data – alarm history, evaporator freezing protection, modification of glycol temperature setpoints, monitoring of glycol temperature setpoints, ambient air temperature, operation of aggregate, fans, pumps, compressor alarms, starting or stopping the device, high/low pressure alarm from transducers; 2) the operating volume of the unit measured in accordance with the Annex to the Regulation of the Minister of the Environment of 14 June 2007 (i.e. Journal of Laws 2014, item 112) on permissible environmental noise levels (in the immediate vicinity of the ice rink there are single-family residential areas), may not cause exceedance of permissible environmental noise levels according to the Annex to the Regulation of the Minister for the Environment on permissible environmental noise levels (noise level may not exceed 55dB). The refrigeration unit should bear the CE marking and the EU declaration of conformity. Where the equipment offered is subject to pressure equipment requirements in accordance with Directive 2014/68/EU (PED), the Contractor must also provide documentary evidence that the equipment complies with the requirements of that Directive. 9. Bands of ice rinks: to be assured
Contract
Who has won here before
| Company | Awards | Period |
|---|---|---|
| FHU "JUTRZENKA” JANINA GIDZIŃSKA | 2 | 2023–2025 |
| Salon Podłóg Bergson- Krzysztof Góra | 1 | 2025 |
| Jutrzenka Serwis sp. z o.o. | 1 | 2026 |
| Jutrzenka Serwis Spółka z o.o. | 1 | 2025 |
How to bid
Guide: how to apply on e-Zamówienia (Polen) → Registration, signature, fees — from the operator's bidder manual.